SCPI Commands Appendix C
Series E4360 User’s Guide 105
SCPI Command
Description
MEMory
:COPY:TABLe <CPD>
Copies the selected table to non-volatile memory
:DELete
[:NAME] <CPD>
Deletes the specified table in volatile/non-volatile memory
:ALL
Deletes all tables in volatile and non-volatile memory
:TABLe
:CATalog?
Returns all table names in volatile/non-volatile memory
:CURRent
[:MAGnitude] <NRf>{,<NRf>}
Programs a list of current points for a new table
:POINts?
Returns the number of current points in the active table
:SELect [<CPD>]
Creates a new table in volatile memory
:VOLTage
[:MAGnitude] <NRf>{,<NRf>}
Programs a list of voltage points for a new table
:POINts?
Returns the number of voltage points in the active table
OUTPut
[:STATe] <Bool> [,(@chanlist)]
Enables/disables the specified output channel(s)
:COUPle
[:STATe] <Bool>
Enables/disables channel coupling for output sync
:CHANNel [<NR1> {,<NR1>}]
Selects which channels are coupled
:INHibit :MODE LATChing | OFF
Sets the remote inhibit mode
:PON:STATe RST | RCL0
Programs the power-on state
:PROTection
:CLEar [(@chanlist)]
Resets latched protection
:COUPle <Bool>
Enables/disables channel coupling for protection faults
:OT
:AMBient:MARGin? [,(@chanlist)]
Returns the margin between ambient and OT trip temp
:TUNNel:MARGin? [,(@chanlist)]
Returns the margin between heat sink and OT trip temp
SENSe
:DLOG
:CLOCk TRIGger | TIMer [,(@chanlist)]
Specifies the measurement capture trigger source
:TINTerval <NRf> [,(@chanlist)]
Sets the time interval for capturing measurements
[SOURce:]
CURRent
[:LEVel]
[:IMMediate][:AMPLitude] <NRf+> [,(@chanlist)]
Sets the output current in Fixed mode
:DTABle
:SASimulator
[:IMMediate]? [(@chanlist)]
Returns the calculated DAC table used for the SAS settings
[:IMMediate]:IMP? [(@chanlist)]
Returns the calculated DAC table Imp value
[:IMMediate]:ISC? [(@chanlist)]
Returns the calculated DAC table Isc value
:LIST? <NR1> [,(@chanlist)]
Returns the calculated DAC table used for the step
:LIST:IMP? <NR1> [,(@chanlist)]
Returns the calculated DAC table Imp value for the step
:LIST:ISC? <NR1> [,(@chanlist)]
Returns the calculated DAC table Isc value for the step
:TABLe
[:IMMediate]? <CPD> [,(@chanlist)]
Returns the calculated DAC table used for the table
[:IMMediate]:IMP? <CPD> [, (@chanlist)]
Returns the calculated DAC table Imp value for the table
[:IMMediate]:ISC? <CPD> [, (@chanlist)]
Returns the calculated DAC table Isc value for the table
:MODE FIXed | SAS | TABLe [,(@chanlist)]
Sets the operating mode of the instrument
:DTABle 256 | 4096 [,(@<chanlist>)]
Specifies the size of the table in points
:PROGramming INTernal | EXTernal
[,(@<chanlist>)]
Specifies the programming source in auto-parallel
operation

Other manuals for Keysight Technologies E4360A