5. Use a flat-bladed screwdriver and carefully pry up on the side of the battery indicated by the
arrow.
6. Install the new battery. Make sure that the positive side (+) is facing up. Place the battery under
the small spring clips indicated by the circle, then push down on the opposite end of the battery
indicated by the red arrow. The top of the small spring clips should be visible after the battery is
seated (see red circle).
7. Replace the ribbon cables by fully inserting the cables into the connector; then pushing down on
the locking tab to secure the cables.
8. Replace the Control board and top cover when finished.
9. Reset the date and time (see Clock Setup).