Model Features and Options
Model Features
5 kWModels -
10 kWModels -
RP7931A/RP7941A
RP7933A/RP7943A
RP7932A/RP7942A
RP7935A/RP7945A RP7936A/RP7946A
RP7951A/RP7961A
RP7952A/RP7962A RP7953A/RP7963A
Voltage, Current,
& Power Ratings
0 to 20 V
0 to ±400 A (5 kW)
0 to ±800 A (10 kW)
0 to 80 V
0 to ±125 A (5 kW)
0 to ±250 A (10 kW)
0 to 160 V
0 to ±125 A (10 kW)
0 to 500 V
0 to ±20 A (5 kW)
0 to ±40 A (10 kW)
0 to 950 V
0 to ±20 A (10 kW)
3-phase, 200/208 VAC
nominal
RP7931A/RP7933A RP7932A/RP7935A RP7936A RP7951A/RP7952A RP7953A
3-phase, 400/480 VAC
nominal
RP7941A/RP7943A RP7942A/RP7945A RP7946A RP7961A/RP7962A RP7963A
2-quadrant source-
sink operation
Yes Yes Yes Yes Yes
Output autoranging 1.6-to-1 2-to-1 2-to-1 2-to-1 2-to-1
Output lists Yes Yes Yes Yes Yes
Arbitrary waveforms Yes Yes Yes Yes Yes
Adjustable bandwidth Voltage & Current Voltage & Current Voltage & Current Voltage only Voltage only
Parallel operation Yes Yes Yes Yes Yes
Master-slave mode Yes Yes Yes Yes Yes
Voltage & current
programming
Yes Yes Yes Yes Yes
Output resistance
programming
Yes* Yes* Yes Yes Yes
Voltage & current
measurement
Yes Yes Yes Yes Yes
Amp-hour, Watt-hour,
& power measurement
Yes Yes Yes Yes Yes
Array readback Yes Yes Yes Yes Yes
Adjustable sampling Yes Yes Yes Yes Yes
External datalogging Yes Yes Yes Yes Yes
Under-voltage
protection
Yes Yes Yes No No
SDS unitavailable No No No Yes Yes
*Requires firmware version B.03.02.1232 and up.
Keysight RP7900 Series Operating and Service Guide 33
1 Quick Reference