MONO OPERATION
minimum impedance of 1 ohm
12V
For multiple amplifi er installations where distribution blocks are used,
each amplifi er should have its proper-rated fuse, or breaker, installed
between the amplifi er and the distribution block within eighteen inches of
the block, or on the distribution block if it provides for fusing. The primary
power wire should also be fused between the battery and distribution
block, within eighteen inches of the battery’s positive terminal, with a
fuse or breaker rated at least to the sum of the individual amplifi er’s fuse
values. Use wiring of the same gauge and current capacity as your
power and ground wires.