8. Locations to Avoid
In the garage. Products of combustion are present when you start your automobile.
Normal cooking may cause nuisance alarms. If a kitchen alarm is desired, it should have an alarm
silence feature or be a photoelectric type.
Do not install within 1.8 m (6 ft) of heating or cooking appliances.
Less than 10 cm (4”) from the peak of an “A” frame type ceiling.
In an area where the temperature may fall below 4.4°C (40°F) or rise above 37.8°C (100°F), such as
garages and unfinished attics.
In dusty areas. Dust particles may cause nuisance alarm or failure to alarm.
In very humid areas (above 95% RH, non-condensing). Moisture or steam can cause nuisance alarms.
In insect-infested areas.
Smoke alarms should not be installed within 0.9m (3 ft) of the door to a bathroom containing a tub or
shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans,
or other high air flow areas.
Near lights. Electronic “noise” generated by the electronics may cause nuisance alarms.
Do not install near vents, flues, chimneys or any forced/unforced air ventilation openings.
Do not install near fans, doors, windows or areas directly exposed to the weather.
Smoke alarms are not to be used with detector guards unless the combination (alarm and detector
guard) have been evaluated and found suitable for that purpose.