Issue: 10/2010

 

U The ground PE wiring (16
2
) should be highly exible and nely-stranded (like
welding cable) to drain the high-frequency ignition voltage.
U Do not use wires in lamphouse cable to connect the additional dowser.
Lay dowser connection in lamphouse tube as short as possible.
U Do not use unit parts as climbing aid.
U If possible the heat exchanger must not have more than 10 m distance to projec-
tor and refrigerating set must not have more than 15 m distance to heat exchanger.
If environment temperature is high and wires are long, the hose is to be isolated
because of condensation water.
U The cooling water temperature has to be more than 15° C, to avoid a precipitation of
condensed water on the lm gate and the front gate.
 
 
X 
Use only Kinoton type 3672 oil.
1
4
2
3
Intermittent movement (Maltese cross)
Oil gauge glass with oil level rings(red and green)
Oil gauge cap
Vent hose