4
4
-
19
FUNCTION DESCRIPTION AND OPERATING TIPS
td2O434A td2O435B
CARBON LOAD AND WARNING LEVELS
2. Carbon load and warning level 2
: Carbon load 110% - 120% ma-
nual regeneration required engine
torque reduced (30%)
If the DPF regeneration process is
not performed in the rst warning le-
vel, the corresponding warning lamp
comes on. Make sure to press the
"Regeneration" button in this condi-
tion.
1. Carbon load and warning level 1
: Carbon load 100% - 110%
manual
regeneration required
engine torque
reduced (30%)
If this warning lamp comes on, you
must press the "regeneration" button.
(Refer to page 4-11.)
td2O436A
3. Carbon load and warning level 3
: Carbon load over 120% DPF limit
/ limp-home mode activated engi-
ne torque reduced (50%)
If the DPF regeneration process is
still not performed, the engine CHE-
CK lamp comes on. In this case, the
DPF needs replacement.
TD200-호주향-DK4810,5310,5810(HS)-019 19 2015-02-11 오후 2:58:06