Kipor IG6000 - Low Oil Alarm Inspection

Kipor IG6000
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Engine oil change
1Remove dipstick and oil drain bolt and drain out the used oil.
2Tighten the oil drain bolt securely.
3Pour the specified amount of fresh engine oil through the oil filler port.Engine oil capacity : 1.2 qt
(1.1L)
Recommended engine oil
SE, SF engine oil classified by API or SAE10W-30 engine oil which same as SG grade.
Use SAE10W-30 engine oil when the temperature is below 10
. Use SE,
or SAE5W-30 engine oil which same as SG grade when the temperature is below -15 .
Select the appropriate viscosity for the average temperature in your area.
4Check the oil level after refilling. Add the oil to the limit level.
5Tighten the dipstick.
Drain the used oil while the engine is warm. Warm oil drains quickly and completely.
Please dispose of the used motor oil in a manner that is compatible with the environment. We suggest
you take used oil in a sealed container to your local recycling center or service station for reclamation.
3.3 Low Oil alarm inspection
(1)Disconnect the orange oil alarm wire when the engine stops and ground the terminal specified in the
diagram and confirm that the alarm light is on and the engine stops or won’t restart.
Outlet terminal of ignitor
Outlet terminal of oil alarm Ground through engine cover