38
(2) Trigger
● Insert each meter pen to each trigger outgoing line to measure trigger resistance.
Trigger head
resistance
80~130Ω
C. Adjustment
Adjust the clearance between the trigger head and rotor.
Trigger head
clearance
.020-.029 in. (0.50~0.75 mm)
Insert the feeler gauge between the bulge on the trigger head and the rotor to measure clearance.
Loosen the two bolts on the bracket to obtain the proper. When tightening, apply equal torque to both
mounting bolts to prevent “cocking” the trigger to one side. Recheck the clearance after the adjustment
has been made.