LIGHTING AND PANIC CONTROL OPERATION WITH IP-1 INSTALLED
THERE ARE TWO OPTIONS FOR CONTROLLING LIGHTS:
Patented Timed Lighting with AutoPanic (default):
• To turn lights on and activate the lights-off timer and AutoPanic alarm, press the “Light” button on the
75LC
•
The IP-1 beeps and blinks for 40-seconds
•
Press the IP-1 within 40-seconds to:
•
“Check in” and keep the lights on for as long as the door remains closed
•
Lock out the 75LC “Light” button and prevent the light from being turned off from outside the walk-in
•
Activate the 20-minute AutoPanic timer
• If the IP-1 is not pressed within 40-seconds, the lights will turn off
•
After 20-minutes, the IP-1 beeps and blinks again for 40-seconds
•
Press the IP-1 to “check in“ and restart the AutoPanic timer
•
The 20-minute alarm cycle will repeat for as long as a person remains in the walk-in without opening the door
•
If the IP-1 is not pressed within 40-seconds, the 75LC will automatically sound a panic alarm
Untimed, Manual Light Control (replaces light switches):
•
To turn lights on, press the “Light” button on the 75LC
•
To turn lights off, press the “Light” button again