Gas Connection Requirements
Style 2 - Built-In Outdoor Grills
Natural Gas
Built-in grill models are equipped for use with
Natural gas. They are design-certied by CSA
International for LP (propane or butane) gases
with appropriate conversion.
Built-in models are set for Natural gas use and
have a pressure regulator with ½" female pipe
threads.
A. Grill gas pipe
B. New CSA International approved
outdoor” exible gas supply line
C. Rear of grill
D. To Natural gas supply
A
B
C
D
The supply line shall be equipped with an
approved shutoff valve. This valve should be
located in the same area as the grill and should
be in a location that allows ease of opening
and closing. Do not block access to the shutoff
valve. The valve is for turning on or shutting
off gas to the grill.
LP Gas Conversion Using a Local LP Gas
Supply
Conversion must be made by a qualied per-
son. A qualied Natural gas technician shall
provide the LP gas supply to the selected grill
location in accordance with the National Fuel
Gas Code ANSI Z223.1/NFPA 54 - latest edi-
tion, and local codes.
To convert to LP gas, the LP Gas Conversion
Kit Part Number W10118099 must be used.
Follow instructions included with kit.
A.Grill gas pipe
B. New CSA International approved
outdoor exible gas supply line
C. Rear of grill
D. To local gas supply
A
B
C
D
LP Gas Conversion Using a 20 lb LP Gas
Fuel Tank
To convert to LP gas, the LP Gas Conversion
Kit Part Number W10118099 must be used.
Follow instructions included with kit. A 20 lb LP
gas fuel tank must be purchased separately.