10
ۣૐ ۞ইૐ઺Ҵ ೠҴ࢑সӏѺ ಿ૕҃৔మ
TechnicalParametersforboilercombinationheaters
ThefollowingproductdatasatisfytherequirementsoftheEURegulationsNo.813/2013AnnexII5.
KITURAMI K1
COMBIErP
Symbol(unit) K1-22E K1-28E K1-34E K1-40E
Rated Heat Output
At rated Heat
Output (Arithmetic
mean)
P4(kW) 10.95 13.25 16.55 22.6
At 30% of rated
heat output
P1(kW) 3.6 4.4 5.3 7.3
AuxiliaryelectricityConsumption
At full load
(Arithmetic mean
input)
elmin(kW) 0.028 0.035 0.038 0.047
At part load (30%
of Arithmetic)
elmin(kW) 0.019 0.02 0.022 0.020
Instandbymode PSB(kW) 0.005 0.005 0.003 0.005
SeasonalSpaceHeatingEnergyEfciency
SeasonalSpace
Heating Energy
Efciency(GCV)
ηs(%) 91 90 91 91
At rated Heat
Output (Arithmetic
mean)(GCV)
η4(%) 89.4 88.9 88.7 88.3
At 30% of rated
heatoutput(GCV)
η1(%) 96.8 95.6 96 95.6
ForCombinationHeaters
Declareloadprole - XL XL XL XL
Daily electricity
consumption
Qelec(kWh) 0.230 0.230 0.218 0.218
Water heating
energyefciency
ηwh(%) 80 80 81 81
Daily Fuel
Consumption
Qfuel(kWh) 15.917 15.917 15.553 15.730
OtherItems
StandbyHeatLoss Pstby(kW) 0.090 0.075 0.056 0.053
Emissionsof
NitrogenOxides
NOx(mg/kWh)
15(NCV)
13(GCV)
17(NCV)
16(GCV)
9(NCV)
8(GCV)
16(NCV)
15(GCV)