9.1 Error Codes
▪Ifafaultoccursontheboiler,anerrorcodemaybeshownbytheControlPanelScreen.
▪Thecodesareaashingnumber.
▪Bypressingthe'PowerButton'toresettheboiler,itispossibletoreworktheboiler.
▪Ifthisdoesnothaveanyeffect,orthecodesaredisplayedregularlyfurtherinvestigationisrequired.
Display
Code
CodeDescription PossibleRemedies
Er.01 Ignition Failure
•Makesurethatthemaingassupplyvalveisopen.
•Makesurethatthegassupplyandinletgasiswithinspecication.
Er.02
Failure Flame Detection
•Cleantheamewindow.
•Makesurethatthefrontcoverisclosedsecurely.
•Checktheamesensor.
Flame Detect before
BurnerIgnites
•MeasurethecurrentfromtheFlameSensorwhenthereisnoame.
•Toresetthiserrorcode,thepowerneedstobedisconnectedandthen
connectedagain.
Er.03 FlameLoss
•Cleantheintakeairpipe.
•Makesurethatthemaingassupplyvalveisfullyopenorhaveaprofessional
tocheckthegassupplypressure.
Er.06 NoInputRPMSignal
•Checkfanmotor
•Makesurethattheconnectorissecured
Er.07
Fan Speed Error
(High rpm)
•Toresetthiserrorcode,thepowerneedstobedisconnectedand
thenconnectedagain.
Er.08
Communication Error
betweenControlPanel
andCircuitBoard
•CheckconnectionsfromCircuitBoardtoControlPanel.
•Toresetthiserrorcode,thepowerneedstobedisconnectedandthen
connectedagain.
Er.10
Fan Speed Error
(Lowrpm)
•Checkfanmotor
•Makesurethattheconnectorissecured
Er.04
DHWOutletThermistor
Open or Short Circuit
•Ensureconnectionsaresecure.
•Checksensorresistance.Ifresistanceiszero,replacethesensor.
Er.05
Heating Storage
ThermistorOpenorShort
Circuit
Er.14/Er.19
bimetal(Tappingoverheat)
Open or Short Circuit
Er.18
BurnerOverheat
ThermistorOpenorShort
Circuit
Er.15
ExhaustThermistorOpen
or Short Circuit
Er.16
ExhaustThermistor
Abnormality
Er.21
EarthquakeThermistor
Open or Short Circuit