Instruction
Manual
Instruction
Manual
CL100
ENGLISH
www.kleintools.com
F o r P r o f e s s i o n a l s . . . S i n c e 1 8 5 7
®
CL100
A
AC
CL100
AUTO
• 3-1/2 DIGIT
1999 COUNT LCD
• AUTO / MANUAL
RANGE
• MAX HOLD
• DATA HOLD
• BACKLIGHT
• WORKLIGHT
ENGLISH
CL100
Instruction Manual
GENERAL SPECIFICATIONS
The Klein Tools CL100 is a multi-featured clamp meter. It measures AC / DC
voltage, AC current, and resistance. It can also test diodes and continuity.
• Operating Altitude: 2000 meters
• Relative Humidity: 75% max
• Operating Temperature: 0°C / 32°F to 40°C / 104°F
• Storage Temperature: -10°C / 10°F to 50°C / 122°F
• Accuracy Temperature: 18°C / 64°F to 28°C / 82°F
• Temperature Coefficient: 0.1*(specified accuracy) / °C
• Sampling Frequency: 2.5 samples per second
• Dimensions: 8.2" x 3.0" x 1.4"
• Weight: 9.9 oz.
• Calibration: Accurate for one year
• CAT Rating: CAT III 600V
• Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring
a known voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from
the metal probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes
are connected.
• Use caution when working with voltages above 60V DC,
or 25V AC RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock,
replace batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out
power before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
SYMBOLS
~
AC Alternating Current Warning or Caution
DC Direct Current Dangerous levels
DC/AC Voltage or Current Double Insulated Class II
Ground
Safe for disconnect
from live conductors
AC Source
Question and Answer IconNeed help?

Do you have a question about the Klein Tools CL100 and is the answer not in the manual?

Klein Tools CL100 Specifications

General IconGeneral
BrandKlein Tools
ModelCL100
CategoryMultimeter
LanguageEnglish

Summary

Feature Details

Backlight and Worklight

Activates worklight and backlight, turning off automatically after 15 seconds.

Auto Power-Off

Device powers off after 15 minutes non-use; can be disabled by holding HOLD.

Function Instructions

AC Current Measurement

Instructions for measuring AC current up to 600A, including wire centering.

AC/DC Voltage Measurement

Instructions for measuring AC/DC voltage up to 600V.

Diode and Continuity Test

Diode Measurement

Displays forward voltage drop when biased, or 'O.L.' when reverse biased.

Continuity Test

Displays resistance and sounds buzzer if resistance is less than 600 Ohms.

Electrical Specifications

DC Voltage Measurement Specifications

Details ranges, resolution, accuracy, and overload protection for DC voltage.

AC Voltage Measurement Specifications

Details ranges, resolution, accuracy, overload protection, and response for AC voltage.

AC Current Measurement Specifications

Details ranges, resolution, accuracy, and frequency range for AC current.

Resistance Measurement Specifications

Details ranges, resolution, accuracy, overload protection, and open circuit voltage.

Product Information

Diode Test Specifications

Specifies forward DC current, resolution, reverse DC voltage, and overload protection.

Continuity Test Specifications

Specifies resolution, overload protection, and open circuit voltage.

Warranty Information

Details the two-year warranty, limitations, and contact information for claims.

Cleaning Instructions

Guide on how to clean the instrument using a damp cloth, avoiding abrasives.

Storage Recommendations

Advice on removing batteries for prolonged storage and avoiding extreme conditions.

Disposal and Recycling

Indicates symbol for separate collection and correct disposal of equipment.