ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV
±(1.2% + 5 digits)
600.0V 100mV
1000V 1V ±(1.7% + 5 digits)
DC Voltage
(V DC)
600mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV
±(0.8% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 3 digits)
AC + DC
Voltage
(V)
6.000V 1mV
±(2% + 6 digits)
60.00V 10mV
600.0V 100mV
1000V 1V
Input Impedance: ≥
10MΩ
Frequency Range:
45 to 400Hz (AC only)
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
60.00A 10mA ±(2.5% + 10 digits)
600.0A 100mA ±(2.0% + 10 digits)
AC Current (A)
Inrush
60.00A 10mA
±(10.0% + 10 digits)
600.0A 100mA
DC Current (µA) 200µA 1µA ±(0.9% + 6 digits)
Frequency Range: 50 to 60Hz (AC only)
Resistance
600.0Ω 0.1Ω ±(1.2% + 5 digits)
6.000KΩ
±(1.2% + 3 digits)
60.00kΩ 10Ω
600.0kΩ 100Ω
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 5 digits)
Maximum Input: 600V AC RMS or 600V DC
Capacitance
60.00nF 0.010nF ±(4.0% + 25 digits)
600.0nF 0.1nF
±(4.0% + 8 digits)
6.000µF 0.001µF
60.00µF 0.01µF
600.0µF 0.1µF
6000µF 1µF ±(10.0% + 9 digits)
Maximum Input: 600V AC RMS or 600V DC