Page #8 background imageLoading...
Page #8 background image
8
DC CURRENT 200mA to 10A
1. For DC currents more than 200mA and less than 10A, insert
RED test lead into 10A jack
3
, and BLACK test lead into COM
jack
4
, and rotate Function Selector Switch
2
to the
10A DC setting.
DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate Function Selector Switch
2
to the
highest V DC (
) setting (600V).
2. Measure voltage and rotate the Function Selector Switch
to successively lower V DC (
) settings to obtain higher
resolution measurements.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
NOTE: The hazardous voltage indicator will appear for voltages >30V.
NOTE: Do not attempt to measure more than 600V or 200mA.
Red lead Black lead
Red leadBlack lead
ENGLISH
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM325 and is the answer not in the manual?

Klein Tools MM325 Specifications

General IconGeneral
Diode testYes
Product typeDigital multimeter
Product colorBlack, Orange
DC current range0 - 10 A
DC voltage range0 - 600 V
Housing materialAcrylonitrile butadiene styrene (ABS)
Resistance range0 - 2000000 Ω
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Sustainability certificatesUKCA
Battery typeAAA
Power sourceBattery
Number of batteries supported2
Weight and Dimensions IconWeight and Dimensions
Depth162 mm
Width79 mm
Height46 mm
Weight250 g