OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the V
setting.
NOTE: The meter defaults to AC measurement. Press the "SEL"
button
10
to toggle between AC and DC modes. "AC "or "DC" on the
LCD indicates which mode is selected.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE: If "" appears on the LCD, the test leads are being applied
to the circuit in reverse polarity. Swap the position of the leads to
correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
NOTE: The Hazardous Voltage indicator appears for voltages >30V.
Black lead
Red lead

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM450 and is the answer not in the manual?

Klein Tools MM450 Specifications

General IconGeneral
Product typeDigital multimeter
DC voltage range600 - 600 V
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Resistance resolution50 Ω
Resolution (frequency)50 Hz
Temperature measurement range-40 - 1000 °C
Display digits4000 digits
Battery typeAAA
Power sourceBattery
Number of batteries supported2
Weight and Dimensions IconWeight and Dimensions
Depth165 mm
Width80 mm
Height28 mm
Weight258 g