13
OPERATING INSTRUCTIONS
CONTINUITY
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
to the
Continuity/Resistance
setting.
NOTE: The meter defaults to Continuity testing in this mode. Ensure
that the Continuity Testing icon
is visible on the display. If not,
press the "SEL" button
10
once.
2. Remove power from circuit.
3. Test for continuity by connecting conductor or circuit with test
leads. If resistance is measured less than 50Ω, an audible signal
will sound and display will show a resistance value indicating
continuity. If circuit is open, display will show "OL".
DO NOT attempt to measure continuity on a live circuit.
Black lead
Red lead

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Klein Tools MM450 and is the answer not in the manual?

Klein Tools MM450 Specifications

General IconGeneral
Product typeDigital multimeter
DC voltage range600 - 600 V
Measuring categoryCAT III 600V
Placement supportedHandheld multimeter
Resistance resolution50 Ω
Resolution (frequency)50 Hz
Temperature measurement range-40 - 1000 °C
Display digits4000 digits
Battery typeAAA
Power sourceBattery
Number of batteries supported2
Weight and Dimensions IconWeight and Dimensions
Depth165 mm
Width80 mm
Height28 mm
Weight258 g