4
ELECTRICAL SPECIFICATIONS
CAPACITANCE (AUTO-RANGING)
Range Resolution Accuracy
40.00nF 10pF ±(3.5% + 10 digits)
400.0nF 0.1nF
±(3.0% + 5 digits)4.000μF 1nF
40.00μF 10nF
400.0μF 0.1μF ±(3.5% + 5 digits)
Maximum Input: 600V DC or 600V AC RMS
FREQUENCY (AUTO-RANGING)
9.999Hz 0.001Hz
±(1.0% + 5 digits)
99.99Hz 0.01Hz
999.9Hz 0.1Hz
9.999kHz 1Hz
50.00kHz 10Hz
Sensitivity:
>
2V to 220V RMS
Maximum Input: 600V DC or 600V AC RMS
DUTY CYCLE
1.0% to 99.9%
0.1% ±(1.2% + 2 digits)
Pulse Width: >100us, <100ms
Frequency Width: 5Hz to 10kHz
Sensitivity:
>
2V to 220V RMS
Maximum Input: 600V DC or 600V AC RMS
TEMPERATURE
-40°F to 10°F 1°F ±(1.2% + 7°F)
11°F to 1832°F 1°F ±(1.2% + 6°F)
-40°C to -12°C 1°C ±(1.2% + 4°C)
-11°C to 1000°C 1°C ±(1.2% + 3°C)
ENGLISH