Why is my KMT Streamline SL-V 50 Plus Cutter pump not starting?
- DDr. Thomas GuerreroNov 22, 2025
The pump may not start due to several reasons: * The emergency stop button may be depressed, in which case you should pull the e-stop button out. * The main power may be disconnected, so check the main power and verify that the main power disconnect is on. * The control power may have been interrupted, so check the power supply circuit for a tripped breaker. * Check the input and output of the 24 volt DC power supply. * Check the 2K1 relay. * A protection fault may have been activated, so check the display panel for fault messages. * The motor overload relay may have been tripped; identify the source of the overload, remedy the problem, and reset the overload relay. * The inlet water valve may be turned off; press the reset button on the Run Screen to reset the water valve...