What to do if the KMT Streamline SL-V 50 Plus pump quits running?
- LLinda ZavalaAug 26, 2025
If the pump quits running, it could be due to: * Unsafe operation being detected, so check the display panel for fault messages. * Electrical power interruption, so check the power supply circuit for a tripped breaker. * Check the input and output of the 24 volt DC power supply. * Verify that power is available at the main power source. * Check the 2K1 relay coil. * Check the 4K0 relay. * The motor overload relay has been tripped; identify the source of the overload, remedy the problem, and reset the overload relay.