    William BarryNov 21, 2025
    Why is my KMT Cutter pump not starting?
    • K
      Kyle Garcia Jr.Nov 22, 2025
      The pump may not start due to several reasons: * The emergency stop button may be depressed, in which case you should pull the e-stop button out. * The main power may be disconnected, so check the main power and verify that the main power disconnect is on. * The control power may have been interrupted, so check the power supply circuit for a tripped breaker. * Check the input and output of the 24 volt DC power supply. * Check the 2K1 relay. * A protection fault may have been activated, so check the display panel for fault messages. * The motor overload relay may have been tripped; identify the source of the overload, remedy the problem, and reset the overload relay. * The inlet water valve may be turned off; press the reset button on the Run Screen to reset the water valve...
  • M
    Maria WilliamsAug 25, 2025
    What to do if the KMT Streamline SL-V 30 Plus Cutter pump quits running?
    • A
      Andrew RobinsonAug 26, 2025
      If the pump quits running, it could be due to: * Unsafe operation being detected, so check the display panel for fault messages. * Electrical power interruption, so check the power supply circuit for a tripped breaker. * Check the input and output of the 24 volt DC power supply. * Verify that power is available at the main power source. * Check the 2K1 relay coil. * Check the 4K0 relay. * The motor overload relay has been tripped; identify the source of the overload, remedy the problem, and reset the overload relay.
  • R
    reyeskurtAug 27, 2025
    Why is there no control power to my KMT Streamline SL-V 30 Plus?
    • A
      Alison HahnAug 27, 2025
      If there is no control power, the possible causes are: * A tripped circuit breaker, so check the input and output of all circuit breakers. * A power supply fault, so check the input and output voltages at the power supply. * The emergency stop button is depressed, so pull the e-stop button out. * The master control relay is not energized, so verify that the contactor coil is pulling in on the master control relay. * Contact set failure on the master control relay, so verify that the contact sets on the master control relay are changing states when the relay is energized.
  • E
    Erin DuranAug 27, 2025
    What to do if the console display and lights do not illuminate on KMT Streamline SL-V 30 Plus?
    • E
      Ellen HarrisAug 27, 2025
      If the console display and lights do not illuminate, check for the following: * Ensure the emergency stop button is not depressed; pull it out if it is. * Verify main power is connected and the main power disconnect is on. * Check the power supply circuit for a tripped breaker. * Check the input and output of the 24 volt DC power supply. * Check the 2K1 relay.
  • T
    Tiffany HunterAug 28, 2025
    What causes high oil temperature resulting in shutdown in KMT Streamline SL-V 30 Plus?
    • H
      heathersantiagoAug 28, 2025
      High oil temperature leading to a shutdown can be caused by: * Restricted cooling water flow, so check the cooling water source for proper temperature and flow rate. * A water modulating valve stuck open or closed, in which case you should replace the valve. * Scale build-up in the heat exchanger restricting the flow, so the heat exchanger will need to be flushed or replaced. * Air cooler temperature switch not operating properly, so replace the switch. * No power to cooler fan motor, so check the power supply to the fan motor.
  • S
    Samantha MartinSep 15, 2025
    What causes water leaking from the weep hole on the hydraulic cylinder head flange of KMT Streamline SL-V 30 Plus?
    • M
      Mr. Edward DelacruzSep 15, 2025
      If water is leaking from the weep hole on the hydraulic cylinder head flange, it could be due to: * A failed high pressure seal assembly, so replace the high pressure seal assembly. * A damaged plunger, so check the plunger for longitudinal scratches or flaws. If detected, replace the plunger or return to KMT Waterjet for evaluation and rework. * Seal material buildup on plunger, so polish the plunger surface. * A damaged high pressure cylinder, so check for scratches, grooves or material buildup on the inside diameter of the cylinder.
  • M
    Michael BarkerSep 12, 2025
    What causes water leaking from the weep hole in the sealing head gland nut of KMT Cutter?
    • L
      leblanccheyenneSep 12, 2025
      Water leaking from the weep hole in the sealing head gland nut can be caused by: * High pressure piping gland nut is not tight and is not sealing properly, so tighten the gland nut to the proper torque specification. * Improper high pressure piping connection, so check the number of exposed threads past the collar on the high pressure piping. Only 1- 1/2 to 2-1/2 threads should be exposed. * Damaged sealing head gland nut, so check the gland nut for cracks due to fatigue. If cracks are detected, replace the gland nut.
  • D
    daniel28Sep 13, 2025
    What causes hydraulic oil leaking from the weep hole in the hydraulic cylinder head of KMT Streamline SL-V 30 Plus Cutter?
    • C
      caitlindavisSep 14, 2025
      If hydraulic oil is leaking from the weep hole in the hydraulic cylinder head, it's likely due to a failed hydraulic cartridge seal. Replace the cartridge seal. If the leak persists, check the plunger for linear scratches or scoring.
  • R
    Ryan MendozaSep 5, 2025
    What causes erratic pressure fluctuations in the KMT Streamline SL-V 30 Plus Cutter?
    • N
      Nancy JohnsonSep 5, 2025
      Erratic fluctuations in operating pressure, or the inability to reach or maintain set pressure, can occur if the screen in the proportional pressure valve is blocked with debris. Remove the valve and clean the screen.
  • W
    Whitney MillerSep 3, 2025
    What to do if the KMT Streamline SL-V 30 Plus Cutter pump shaft will not turn?
    • V
      veronica46Sep 3, 2025
      If the pump shaft will not turn, it could be due to: * The flexible coupling has failed, so replace the flexible coupling. * The hydraulic pump has seized, so replace the hydraulic pump.

Summary

Section 1 Introduction

1.4 Safety

Outlines critical safety precautions, hazards, and lockout/tagout procedures for operation.

Section 2 Installation

2.4 Power Requirements

Details compliance with electrical codes and specifies voltage and ampacity requirements.

Section 3 Maintenance

3.2 Maintenance

Emphasizes routine and preventive maintenance for optimal operation and reliability.

3.3 Maintenance Precautions

Highlights critical safety precautions and procedures before performing maintenance.

Section 4 Operation

4.2 Startup Sequence

Details the startup procedures based on previous stop conditions.

4.10 Run Screen Alarms

Lists alarms displayed on the Run Screen and their indications.

Section 5 Low Pressure Water System

5.4 Service and Maintenance Procedures

Details routine servicing and maintenance for filter, strainer, and booster pump.

Section 6 Recirculation System

6.4 Service and Maintenance Procedures

Covers routine servicing and maintenance for the main hydraulic system components.

Section 7 Hydraulic System

7.4 Service and Maintenance Procedures

Details routine inspection and maintenance for the hydraulic system components.

Section 8 Electrical System

Section 9 High Pressure Water System

9.5 Service and Maintenance Overview

Provides general guidance on high pressure water system maintenance procedures.

Section 10 Troubleshooting

10.2 Troubleshooting Guide

Provides a guide to diagnose problems by observing sounds and operating conditions.

KMT Streamline SL-V 30 Plus Specifications

General IconGeneral
ModelSL-V 30 Plus
CategoryCutter
Max Operating Pressure60, 000 PSI
Abrasive Flow Rate0.5-1.5 lb/min
Cutting Width0.04 inch
Cutting SpeedDependent on material and thickness