Diaphragm pump N85, N86 Servicing
Translation of original Operating and Installation Instructions, english, KNF 121258-121528 01/20 27
9. Servicing
9.1. Servicing schedule
-
Regular inspection for external dam-
age or leaks
-
Regular inspection for external dam-
age or leaks
plates
- Replace when pumping capacity
decreases, or sooner
-
Tab. 16
9.2. Cleaning
When cleaning, make sure that no liquids enter the inside of
t
he housing.
9.2.1. Flushing pump
Before switching off the pump, flush it with air (or with inert gas
if required for safety reasons) under atmospheric conditions
(ambient pressure) for about five minutes.
9.2.2. Cleaning pump
Pump disconnected from mains and de-energized.
WARNING
Dangerous substances in the pump can
c
ause a health hazard.
epending on the substance transferred, caustic
urns or poisoning are possible.
Wear protective clothing if necessary, e.g. pro-
tective gloves.
Take the proper steps to clean the pump.
CAUTION
Danger of burns from hot pump parts
T
he pump head or motor may be hot even after the
ump has been shut off.
Allow the pump to cool off after operation.
Solvent should be used for cleaning only if the head materials
are not corroded (ensure compatibility of the material).
If compressed air is available, blow out the parts.