Troubleshooting
Issue Probable Cause
Unit will not power up
Power switch damaged
Loose wire on switch terminals
Check circuit breaker
Formula volume not accurate
Recalibrate water
Recalibrate detergent
Check for low water pressure
Concentration not accurate
Recalibrate detergent
Check/ replace solution adaptor check valves
Detergent flow meter gears stuck
Detergent flow meter sensor damaged
Detergent alarm stays on
Bad level sensor float
Bad level sensor reed switch
Loose wire on level sensor connection at pc board
Water alarm will not clear
Water pressure too low
Water flow meter gears stuck
Water flow meter sensor damaged
Cannot retrieve reports
No saved data
Invalid date range
USB drive damaged or incompatible
Cannot view report summary
No saved data
Invalid date range
Report showing incomplete
volumes and frequent cycle
interruptions
Staff topping up sink/tubs
Staff needs training
Report showing frequent
temperature alarms
Temp sensor not place at sink bottom
Boiler not able to keep up
Damaged temperature sensor
Too much foam in sink
Place solution hose not under water
Fixed pressure regulator damaged
Detergent Concentration too high
Formulas will not activate
Faulty switch on circuit board
Circuit board loose