Specifications
Case materials #304 stainless steel
Case rating IP-XO
Water solenoid valve 24 VDC
Power supply
Wall Mount Type,
In: 100-240 VAC 1A 50-60 Hz
Out: 24 Volts DC 1.67A
Power supply (alternate)
Wall Mount Type,
In: 100-240 VAC,1.4-0.7A, 50-60 Hz
Out: 24 Volts DC 2.5A
Backflow Preventer
Pipe interrupter with atmospheric vent and moving element
DB Type valve suitable for up to Fluid Category 4
Conforms to EN 1717 (KIWA Approvals)
Chemical check valve material Polypropylene/EPDM
Solution discharge hose material PVC
Faucet Spout Chrome plated copper
Chemical suction tubing PVC
Chemical suction tube weight material Ceramic
USB drive recommendation SanDisk
®
Cruzer Glide
Temperature sensor RTD type, +/- 2%
Flow meter materials PVDF (Water), PPS (Chemical)
Unit dimensions/weight
11” H x 9” W x 7.1” D/16 lbs
28 cm x 23 cm x 18 cm/7.25 kg
Electrical Safety
CAN/CSA-C22.2 No. 61010-1-04
UL Std. No. 61010-1 (2nd Edition)
EN 61010-1:2010
Level sensor materials PVC, Polypropylene, ABS
Water connection to unit (North American standard) ½” NPT (14 MM BSP)
Environmental Rating Standard
Designed for Use Indoor Use Only
Installation Category II
Pollution Degree 2
Operating Temperature Range 15°C to 35°C
Operating Humidity Range 10-75% Non-Condensing
Storage Temperature Range 1°C to 52°C
Storage Humidity Range 5-90% Non-Condensing