A-61837 June 2015 4-7
8. On the Device - General tab, click the Diagnostics button. The General-
Diagnostics window will be displayed.
9. Check the Printer check box and click Done.
10. Scan the blank sheet of paper that is in the input elevator.
11. Check the quality of the test pattern. If the test pattern is inconsistent, you
may need to clean the print head on the bottom of the ink cartridge or
change the ink cartridge.
NOTE: Clean the print head by removing it from the printer carrier and
dabbing the print head with a damp cloth.
Acceptable Unacceptable: pattern
is inconsistent