OPERATORS MANUAL
14 19JAN99 – 7C8770
• Check that the correct Bulb and Safelight Filter are in the Safelight and at the
correct distance from the Feed Shelf and work surface.
• • Check that the Top Cover and Panels are tight on the Processor. Check that
there are no leaks in the Lighttight Gasket.
• 10 x 10 cm films - feed films diagonally if they fail to transport reliably.
• Check the time delay. For all transport speeds, the buzzer should sound once
the trailing edge of the film has advanced 75 mm (3 in.) into the Processor.
• • • • Check that the tank solution levels are at the overflow Weirs.
• Check for solution in the Replenishment Tanks. Fill if necessary.
NOTE: Mix developer replenisher in quantities not to exceed a 2-week
supply.
• With a thermometer of known accuracy, check that the temperature of the
developer is correct. If necessary, have qualified service personnel make
adjustments.
NOTE: Check the incoming water temperature. It must be a minimum of 4 C
(7 F) lower than the desired developer temperature.
1. Transport Failure
2. Surface Artifacts
3. Abnormal Film Densities
4. Wet Films
5. Low Solution Levels
6. Overlapping of Films
123456