EasyManua.ls Logo

Kodak X-Omat 2000 - Processing Solutions; Preparing the Solutions; Draining the Tanks

Kodak X-Omat 2000
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATORS MANUAL
8 19JAN99 – 7C8770
Section 3: Processing Solutions
Preparing the Solutions
Figure 6 Processing Tanks with the Splash Guard
and the Drip Tray
Caution
Avoid contamination of the processing solutions.
To avoid spilling solutions from one Tank into the
next one, use the Splash Guard between the
developer and fixer Tanks.
Slowly install or remove the Racks.
Use the Drip Tray when moving Racks to or from
the Processor.
Do not mix more than a 2-week supply of
chemicals.
[1] Mix the volume of processing solution required in
the correct replenisher Tank. Use the instructions
packed with the chemicals to mix the solution.
Note
Refer to Service Bulletin 30, Part No. 632661, for more
information.
[2] Remove the Crossover Assembly and the Rack
from the Tank that is to be filled.
Draining the Tanks
Warning
All drain material must be made of chemically resistant, non-corrosive material. Use PVC or the equivalent. The
Drain must have a minimum diameter of 7.6 cm (3 in.) and no obstructions. See the Site Specifications,
Publication No. 7C8769.
Relatively small amounts of fixer can seriously contaminate the developer. If solutions are changed in both
Tanks, fill the fixer Tank first so that any solution spilling into the developer Tank can be thoroughly cleaned.
Drain only one Tank at a time.
H172_1003AC
H172_1003ACA
SPLASH GUARD
DRIP TRAY

Related product manuals