Controller:
Decision Maker
®
3500
Marine Generator Sets
TP-7044 6/23e
Operation

Table of Contents

Other manuals for Kohler 12EFKOZD

Questions and Answers

  • A
    Autumn WeberAug 25, 2025
    How to address fuel filter restriction in my Kohler Portable Generator?
    • M
      michael94Aug 25, 2025
      If the fuel filter of your Kohler Portable Generator is restricted, clean or replace the fuel filter. The cause is fuel filter restriction.
  • R
    Robert GonzalesAug 25, 2025
    What to do if my Kohler 12EFKOZD Portable Generator runs out of fuel or the fuel valve is off?
    • A
      alexandervillarrealAug 26, 2025
      If your Kohler Portable Generator's fuel tank is empty or the fuel valve is shut off, add fuel and move the fuel valve to the ON position. This is because the fuel tank is either empty, or the fuel valve is shut off.
  • C
    Clinton MirandaAug 26, 2025
    How to fix loose or corroded battery connections on a Kohler Portable Generator?
    • B
      bschmidtAug 26, 2025
      If the battery connections of your Kohler Portable Generator are loose, corroded, or incorrect, verify that the battery connections are correct, clean, and tight. The cause of this problem is that the battery connections are loose, corroded, or incorrect.
  • B
    Brian SmithAug 27, 2025
    What to do if my Kohler 12EFKOZD Portable Generator is experiencing an engine overload?
    • G
      Gregory DavisAug 27, 2025
      If your Kohler Portable Generator experiences an engine overload, reduce the electrical load. The cause is engine overload.
  • L
    Lisa BerryAug 27, 2025
    What to do if my Kohler 12EFKOZD Portable Generator shuts down due to low oil pressure?
    • L
      Lori LeonAug 27, 2025
      If your Kohler Portable Generator experiences a low oil pressure shutdown, check the oil level. This is due to low oil pressure shutdown.
  • M
    Mark RodriguezAug 28, 2025
    How to fix an exhaust system leak on my Kohler 12EFKOZD Portable Generator?
    • P
      Paula DavisAug 28, 2025
      If you discover an exhaust system leak in your Kohler Portable Generator, inspect the exhaust system and replace any inoperative exhaust system components. This is because there is an exhaust system leak.
  • P
    Patrick SolomonAug 29, 2025
    How to secure a loosely installed exhaust system on my Kohler 12EFKOZD?
    • C
      cookandrewAug 29, 2025
      If the exhaust system of your Kohler Portable Generator is not securely installed, inspect the exhaust system and tighten any loose components. This is because the exhaust system is not securely installed.
  • J
    Joshua SimonAug 30, 2025
    What to do if the transfer switch test switch is in the OFF position on my Kohler Portable Generator?
    • T
      Teresa ChurchAug 30, 2025
      If the transfer switch test switch is in the OFF position on your Kohler Portable Generator, move the transfer switch test switch to the AUTO position. This is because the transfer switch test switch is in the OFF position.
  • A
    Alyssa BaileyAug 23, 2025
    What to do if the oil level is low in my Kohler Portable Generator?
    • E
      Erin HuertaAug 23, 2025
      If the oil level is low in your Kohler Portable Generator, restore the oil level and inspect the generator set for any oil leaks. The reason for this is that the oil level is low.
  • M
    Melissa FosterAug 31, 2025
    How to replace a fuse on a Kohler Portable Generator?
    • E
      Erika ThorntonAug 31, 2025
      To replace a fuse on your Kohler Portable Generator, use fuses of the same ampere rating and type (for example: 3AB or 314, ceramic). Do not substitute clear glass-type fuses for ceramic fuses.

Summary

Safety Precautions and Instructions

Accidental Starting

Procedure to prevent accidental starting and disable the generator set safely.

Hazardous Voltage;Moving Parts

Precautions regarding severe injury or death from hazardous voltage and moving parts.

Maintenance and Service Parts

Section 1. Service Views

Section 2. Operation

2.1 Prestart Checklist

Essential checks before starting the generator set to ensure safe and satisfactory operation.

2.11.6 Paralleling Operation

Configuration and setup procedures for operating multiple generator sets in parallel.

2.14 Controller Operation

Explains the controller's modes, start/stop functions, and system status indicators.

2.14.1 Emergency Stop

Procedure for immediate shutdown using the emergency stop switch and subsequent reset.

2.14.6 Controller Resetting

Procedure to restart the generator after a shutdown or clear a warning condition.

Section 3. Scheduled Maintenance

Section 4. Troubleshooting

4.1 Controller Display and Voltage Regulation Troubleshooting Chart

Reference chart for diagnosing and resolving issues related to controller display and voltage regulation.