EasyManua.ls Logo

Kohler 12RES

Kohler 12RES
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 1 Specifications and Features
1.1 Specifications
The generator set specification sheets provide specific
generator and engine information. Refer to the spec
sheet for data not supplied in this manual. Consult the
generator set service manual, engine operation manual,
and engine service manual for additional specifications.
Obtain copies of the latest spec sheets, manuals,
diagrams, and drawings from your local
distributor/dealer.
1.2 Generator
The generator uses Kohler's unique PowerBoosV"
voltage regulation system, which provides instant
response to load changes.
PowerBoost TM ensures reliable motor starting and
consistent voltage levels. PowerBoosV" utilizes a
voltage excitation system that employs a winding
independent of the main output windings to provide
excitation voltage.
1.3 Engine
The generator set has a four-cycle, twin cylinder, air-
cooled Kohler _ engine. The engine operates on
clean-burning natural gas or propane (LP) vapor.
Engine features include:
Efficient overhead valve design and full pressure
lubrication for maximum power, torque, and reliability
under all operating conditions.
Dependable, maintenance-free electronic ignition.
Precision-formulated cast iron construction of parts
subjected to the most wear and tear.
Field-convertible multi-fuel systems that allow fuel
changeover from natural gas to LP vapor (and
vice-versa) while maintaining CARB emission
certification.
Digital spark-advance module (DSAM) optimizes
ignition timing for the selected fuel (12RES).
1.4 Advanced Digital Control
The generator set is equipped with the Kohler ®
Advanced Digital Control (ADC 2100). Controller
features include the following:
Compact controller
Integrally mounted to the generator set
LED display:
Runtime hours
Crank cycle status
Diagnostics
LED display communicates faults:
Auxiliary fault
High battery voltage
High engine temperature
Low battery voltage
Low oil pressure
Overcrank safety
Overspeed
Overfrequency
Overvoltage
Underfrequency
Undervoltage
Membrane keypad for configuration and adjustment
Password-protected user access to menus
Voltage, gain, and speed adjustment
System configuration (system voltage, phase,
and frequency settings, battery voltage, and
generator set model)
Master control switch: Run/Off-Reset/Auto
Remote two-wire start!stop capability
Superior electronics protection from corrosion and
vibration
Potted electronics
Sealed connections
Digital isochronous governor to maintain
steady-state speed at all loads
Digital voltage regulation: -+1.5% RMS no-load to
full-load
Automatic start for programmed cranking cycle
TP-6195 1/04 Section 1 Specifications and Features 1

Table of Contents

Other manuals for Kohler 12RES