To insure continuedsatisfactory operation, thefollowing
items should be checked before each start-up.
Prestart Checklist
OIL LEVEL: Should be at or near full mark (not over).
AIR INLETS: Must be clear and unobstructed.
COMPARTMENT: Interior must be clean.
AIR CLEANER: Must be clean and properly installed.
AIRSHROUDING: Must betightand inproperposition.
EXHAUST: Tail pipe must be clear, muffler and piping
tight and in good condition.
ELECTRICAL: Allconnections (including battery)must
be tight.
Start-Stop Procedure
Move the START-STOP switch into the START position
and hold in this position until the engine is running, then
release. Do not crank engine continuously for more
than 10 seconds at a time. A 60 second cool-down
periodmustbeallowedbetweencrankingattemptsifthe
engine does not start. If the unit fails to start after three
attemptscontactan authorizedservicedealerforrepair.
Failure to follow these guidelines may result in burn out
of the starter motor. To stop, move the switch to the
STOP position. If the generator stops automatically,
identify and correct the problem before attempting to
restart.
Automatic De-Icing
(For Gasoline Models Only)
The automatic de-icing module, mounted between the
carburetor air horn andair cleaner, warms theincoming
airtoreducemoisturefrombeingintroducedintothefuel
system. The system will function whenever the
generator set is running.
The de-icing module is heated by an internal cartridge
heater which is controlled by high- and low-limit
thermostats. The low-limit thermostat (located in the
intake manifold) will turn the cartridge heater on as the
outside air temperature reaches approximately 40_ F
(4_ C). When the de-icing module reaches 185_ F (85_
C) the high-limit thermostat (located in the de-icing
module) will cycle the cartridge heater off preventing
carburetor icing and crankcase breather freeze up.
Whenthegeneratorsetis turnedoff,heatretainedinthe
de-icing module and the carburetor assembly will
reduce condensation from accumulating inside the
carburetor thereby reducing throttle plate icing.
1
FA-277000-B
1. De-Icing Module
Figure 2-1. Automatic De-Icing

Table of Contents

Other manuals for Kohler 4CKM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 4CKM and is the answer not in the manual?

Kohler 4CKM Specifications

General IconGeneral
BrandKohler
Model4CKM
CategoryInverter
LanguageEnglish

Related product manuals