TP-6772 2/14b 53Section 3 Scheduled Maintenance
3.6.6 Siphon Break
A siphon break prevents seawater entry into the
generator set’s engine when the engine exhaust
manifold outlet is less than 230 mm (9 in.) above the
waterline of a fully loaded, docked or stationary craft.
See Figure 3-10. The siphon break may malfunction
when the generator set operates while the craft is in
contaminated waters or saltwater. Use the following
procedure to inspect the siphon break at the intervals
listed in the service schedule.
Siphon Break Inspection
1. Stop the generator set.
2. Remove the retaining cap and remove the reed
valve for inspection. See Figure 3-9.
3. Use a mild detergent to remove residue and
oxidation from the reed valve.
4. Clear blockage from the reed valve opening.
5. Replace the siphon break if the r eed valve is
cracked or if the reed valve material has hardened
or deteriorated.
6. Install the reed valve into the mounting base with
the valve downward. See Figure 3-9, item 2.
7. Install and only finger tighten the retaining cap. Do
not overtighten it.
Note: Ensure that the siphon break’s cap is tight before
operating the generator set.
1. Cap
2. Reed valve
3. Mounting base
1
2
3
Figure 3-9 Siphon Break
m:sm:003:007

Table of Contents

Other manuals for Kohler 5-10EKD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kohler 5-10EKD and is the answer not in the manual?

Kohler 5-10EKD Specifications

General IconGeneral
BrandKohler
Model5-10EKD
CategoryMarine Equipment
LanguageEnglish

Related product manuals