8 TT-1715 2/17
9. Generator Start/Stop
9.1 Read all equipment decals located on the
generator set and safety precautions found in the
provided literature before starting the generator
set.
9.2 The operator can access gauge modes, such as
Start/Stop Mode, after the generator set has been
restored to service and if the controller is powered
ON. See Section 3, Restore the Generator Set to
Service.
9.3 See Section 7, Pushbuttons, and Section 8,
Operating Mode Description, before operating the
remote digital gauge.
10. Using the GEN START Function
10.1 Press the MODE button until GEN STRT appears
on the LCD screen. See Figure 13.
Note: The GEN STRT code will not appear if:
D the generator set is already running.
D an error fault is existing. To clear the fault
code see Section 14.
Note: If the engine does not start within
60 seconds of the command, an alarm will
sound. For all models, the gauge displays
an ERR code. See Section 13, Alarm
Silence/Activate.
10.2 Press the START arrow (up) button Y until
SEND STRT appears on the LCD screen.
Note: If the START arrow (up) button Y is
pressed and released too fast, the gauge
will go back to the normal mode without
sending the start command.
If the generator was successfully started, the gauge will
go into the normal mode and display the HRS characters
(hours screen). Blinking asterisk segments will appear
next to these characters on the LCD screen to indicate
the generator is running.
11. Using the GEN STOP Function
11.1 Press the MODE button until GEN STOP appears
on the LCD screen. See Figure 14.
11.2 Press the STOP arrow (down) button B until
SEND STOP appears on the LCD screen.
If the generator was successfully stopped, the gauge
will go into the normal mode and display the HRS
characters (hours screen) and will not display the
blinking asterisk segments; however, the power is still
activated and the generator set is now in standby mode.
Note: The GEN STOP code will not appear if the
generator set is not running.
Note: If the generator does not stop within 60 seconds
of the command, an alarm will sound. For all
models, the gauge displays an ERR code. See
Section 13, Alarm Silence/Activate.
*
1
2
3
1. MODE pushbutton
2. START (up) arrow button
3. LCD normal (Hours Screen)
Figure 13 Gen START Gauge Pushbutton Functions
*
1
2
3
1. MODE pushbutton
2. STOP (down) arrow button
3. LCD normal (Hours Screen)
Figure 14 Gen STOP Gauge Pushbutton Functions