30 Diagnostic Troubleshooting Codes TP-6903 5/16a
P-Code SPN FMI Description Possible Cause Corrective Action
P0562 167 4 System Voltage Low
Problem with
charging system.
Problem with
charging system or
battery not
maintaining a
nominal system
voltage.
Check harness, engine, and
equipment grounds.
Check the battery fluid levels and
for corrosion on the battery posts.
Check the battery charging
alternator.
Replace the battery and alternator
if needed. Refer to the Engine
Service Manual.
P0563 167 3 System Voltage High
Problem with
charging system
Problem with
charging system or
battery not
maintaining a
nominal system
voltage.
Check the battery and the battery
charging alternator for proper
operation.
Replace the battery and alternator
if needed. Refer to the Engine
Service Manual.
P0603 (No
J1939
DTC)
Internal Control Module
Keep Alive Memory
(KAM) Error
There is no saved
EEPROM data.
Clear the DTC code and turn the
ECM power off. Wait fifteen
minutes and check if the code is
regenerated.
Replace the ECM. Refer to
Section 5.4.
P0604 (No
J1939
DTC)
Internal Control Module
Random Access
Memory (RAM) Error
There is a problem
with the ECM RAM.
Clear the DTC code and turn the
ECM power off. Wait fifteen
minutes and check if the code is
regenerated.
Replace the ECM. Refer to
Section 5.4.
P0605 (No
J1939
DTC)
Internal Control Module
Read Only Memory
(ROM) Error
There is a blank or
corrupted operating
program.
Clear the DTC code and turn the
ECM power off. Wait fifteen
minutes and check if the code is
regenerated.
Replace the ECM. Refer to
Section 5.4.
P0606 (No
J1939
DTC)
ECM/PCM Processor
Either the ECM did
not pass a functional
test or the boot ROM
is corrupt.
Clear the DTC code and turn the
ECM power off. Wait fifteen
minutes and check if the code is
regenerated.
Replace the ECM. Refer to
Section 5.4.
P0610 237 31 Vehicle Options
Programming Error
Not applicable Not applicable
P0615 1321 31 Starter Relay Circuit
Not applicable Not applicable
P0622 167 31 Generator Field/F
Terminal Circuit
Not applicable Not applicable
P0636 2923 4 Power Steering Control
Circuit Low
Not applicable Not applicable
P0637 2923 3 Power Steering Control
Circuit High
Not applicable Not applicable
P0638 3464 7 Throttle Actuator Control
Range/Performance
Desired and actual
throttle positions do
not match.
Troubleshoot the TP sensor
leads. Refer to Section 4.11.
Replace the throttle body. Refer
to Section 5.1.