EasyManuals Logo

Koldfront WAC18001W User Manual

Koldfront WAC18001W
31 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
28
7.2 Error Codes and Sensor Malfunctions
If display indicates an AS error, use the mode button to select "Fan" and LO or HI will be
displayed to indicate the underlying condition. See section 7.3 for additional information.
Display
Error
Solution
AS
Room temperature sensor error.*
1) Check sensor connection to main PCB and
secure any detached or loose connections.
2) Check sensor wire for damage and repair if
possible.
3) Test sensor (see table 7.3) Replace sensor if
defective.
LO
Room sensor is an open circuit.*
HI
Room sensor is a short circuit.*
HS
Electronic heating sensor error.
ES or ●
Defrost sensor is open or short
circuit.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Koldfront WAC18001W and is the answer not in the manual?

Koldfront WAC18001W Specifications

General IconGeneral
BrandKoldfront
ModelWAC18001W
CategoryAir Conditioner
LanguageEnglish

Related product manuals