18
6.5 Cooling Mode
The cooling temperature can be set from 62 to 86℉ (17 to 30℃.)
Sleep, Timer and Energy Saver functions work in cooling mode.
The compressor will run when the difference between the set temperature and the actual ambient
room temperature conforms to the chart below:
1. When TA≤TS (for 1 minute) the compressor turns off.
2. When T1>TS+2℉ the compressor turns on.
6.6 Auto-Defrost Function
The Auto-defrost function operates according to the chart below:
1. When TE is below 30℉ the evaporator will frost. As the unit defrosts the indoor fan will continue to
operate.
2. When the temperature is up over 55℉ the unit will stop defrosting.