20
7 Troubleshooting
7.1 Troubleshooting Guide
Problem
Possible Cause
Solution
Air conditioner does
not function at all.
Wall plug is disconnected.
Insert plug firmly into proper wall outlet.
House fuse blown or circuit
breaker tripped.
Replace fuse with time delay type or reset
circuit breaker.
Power cord is tripped.
Press the RESET button on the power cord.
Unit is turned OFF.
Turn unit ON and set to desired setting.
Ribbon cable to control panel is
disconnected.
Remove front grill and reconnect cable.
Loose or disconnected wiring
on main PCB.
Remove front grill and outer shell. Check all
connections to the PCB and reconnect any
loose or disconnected leads.
Air from unit does
not feel cold
enough.
Room temperature is below
62 (17).
Cooling will not occur until room temperature
rises above 62 (17).
Temperature sensor behind the
front grill and air filter is
touching the cold evaporator.
Realign sensor so it does not touch the
evaporator coil. It should only be sensing the
air temperature leaving the evaporator.
Set temperature is too high.
Set to a Lower temperature.
Compressor is shut-off by
changing modes.
Wait approximately 3 minutes and listen for
compressor to restart when set in COOL
mode.
Air conditioner
cooling, but room is
too warm - ice
forming on cooling
coil behind front grill.
Outdoor temperature below
62 (17).
To defrost the coil, set to FAN ONLY mode.
Air filter may be dirty.
Clean filter. Refer to Installation and Cleaning
section. To defrost, set to FAN ONLY mode.
Thermostat set too cold for
night-time cooling.
To defrost the coil, set to FAN ONLY mode.
Then set temperature to a Higher setting.
Air conditioner
cooling, but room is
too warm - NO ice
forming on cooling
coil behind front grill.
Dirty air filter- air restricted.
Clean air filter. Refer to Installation and
Cleaning section.
Temperature is set too High.
Set to a Lower temperature.
The directional louvers on the
front are positioned improperly.
Position louvers for better air distribution.

Other manuals for Koldfront WTC8001W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Koldfront WTC8001W and is the answer not in the manual?

Koldfront WTC8001W Specifications

General IconGeneral
BrandKoldfront
ModelWTC8001W
CategoryAir Conditioner
LanguageEnglish

Related product manuals