SECTION 2 - SET-UP & OPERATIONS
Open the Top Box Door. Pass the connector of the Candle
of the Top Box. Then, mount
the Candle inside the top box using the two (2) UNC 8-32 screws.
Connect the Candle connector so that the Candle stays horizontal. If
so equipped, secure the frame ground (FG) wire of the Candle with
8-32 screws. Close and lock the
and verify that the Candle illuminates.
If the Tower Light is not required, order P/N
191050 (Cover, Candle Mounting).
(ALL DIMENSIONS ARE IN INCHES)
To ensure proper spacing between machines, the
minimum allowable width of the stand a Konami machine
can be mounted on is 28”.
The Drop Box switch wiring is typically used ONLY
when the machine is not connected to a slot accounting
Open the Main Door. Locate the connector labeled DROP (on
the main cabinet harness). Connect the optional Drop Switch Harness
(P/N 110324). Connect the three spade connectors to the Drop Switch.
Check Drop Switch Operations
If the following problem arises after turning the power on, check
that the Drop Box Switch is installed properly.
not displayed even after the power is turned on again
with the drop-door closed.
The 041 DROP DOOR PORT error message is
No error messages appear when the Sub-Door is
ed error can be detected even with
the power turned off. Reset the error
that the switch is installed correctly.
DROP BOX SWITCH PIN ASSIGNMENT
(SW DROP BOX DOOR (N.O.))
(SW DROP BOX DOOR (N.C.))