7Observethetopbar.
8Makesurethattheinformationfromthesensorisdisplayed.
Ifnecessary,enabletheread-outintheDisplayOptionsdialogbox.
9Ifpossible,useanotherinstrumenttoverifythattheinformationprovidedbytheST90
iscorrect.
10Fillintheresulttables.
Result
Requirements
Results
Positiondataisprovided.
Speeddataisprovided.
Distancedataisprovided.
Headingdataisprovided.
Therelevantcommunicationparametersarerecorded.
Date/Signature:
Relatedtopics
Testingtheinterfaceswithperipheraldevices,page31
Verifyingthecommunicationwiththespeedlog
Inordertooperatecorrectly,theST90systemrequiresinputfromaspeedlog.Thevessel
speedisshownonthetopbarifyouhaveenabledthisintheDisplayOptionsdialogbox.The
communicationwiththesensoristested.
Prerequisites
TheST90systemhasbeensetupwithitshardwareunitsconnectedasspeciedinthe
InstallationManual.
ApersonalcomputerwithasensorsimulatorprogramisconnectedtotheST90system.
Thesimulatorisactive.
Theinterfaceportissetupwiththecorrectcommunicationparameters.
YouarefamiliarwithNMEAandotherrelevantdatagramformats.
Youknowhowtosetuptheparametersforserialandlocalareanetwork(LAN)
communication.
TheST90systemisturnedonandoperatesnormally.
Youneedthefollowingtestequipment: