Chapter 1
1.3 Safety precautions
Table 3 (support for IEC 60601-1-2:2007)
Guidelines and manufacturer's declaration - electromagnetic immunity
This device is intended for use in the electromagnetic environment specied below.
The customer or the user of this device should assure that it is used in such an environment.
Immunity test
IEC 60601
test level
Compliance
level
Electromagnetic environment - guidelines
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms 150 kHz
to 80 MHz
3 V/m 80 MHz
to 2.5 GHz
[3] V
[3] V/m
Portable and mobile RF communications equipment
should be used no closer to any part of this device, includ-
ing cables, than the recommended separation distance
calculated from the equation applicable to the frequency of
the transmitter.
Recommended separation distance
d=[1.2]
P
d=[1.2]
P 80 MHz to 800 MHz
d=[2.3]
P 800 MHz to 2.5 GHz
where P is the maximum output power rating of the trans-
mitter in watts (W) according to the transmitter manufac-
turer and d is the recommended separation distance in
meters (m).
Field strengths from xed RF transmitters, as determined
by an electromagnetic site survey
a
, should be less than the
compliance level in each frequency range
b
.
Interference may occur in the vicinity of equipment marked
with the following symbol:
[NOTE] At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
[NOTE] These guidelines may not apply in all situations. Electromagnetic propagation is a󰀨ected by absorption and
reection from structures, objects and people.
a Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile
radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy.
To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic site survey should be
considered. If the measured eld strength in the location in which this device is used exceeds the applicable RF com-
pliance level above, this device should be observed to verify normal operation. If abnormal performance is observed,
additional measures may be necessary, such as reorienting or relocating this device.
b Over the frequency range 150 kHz to 80 MHz, eld strength should be less than [3] V/m.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Konica Minolta AeroDR System 2 and is the answer not in the manual?

Konica Minolta AeroDR System 2 Specifications

General IconGeneral
BrandKonica Minolta
ModelAeroDR System 2
CategoryMedical Equipment
LanguageEnglish

Related product manuals