EasyManua.ls Logo

Korg Minilogue XD - EG and LFO Section

Korg Minilogue XD
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
EG/LFO section
AMP EG
VCA: Voltage Controlled Amplifier / EG: Envelope Generator
These are the settings for the envelope generator (EG), which
controls changes in the signal volume of the VCA over time.
ATTACK knob [0...1023]
The ATTACK specifies the time required for the EG to reach its maximum level once a new note is
played (note-on).
DECAY knob [0...1023]
The DECAY specifies the time required for the EG to fall to the preset sustain level once the attack
portion of the EG is complete.
SUSTAIN knob [0...1023]
The SUSTAIN specifies the level that will be maintained after the decay time while the key is held
down.
RELEASE knob [0...1023]
The RELEASE specifies the time required for the EG to reach its minimum level (zero) once the
key or trigger is released (note off).
EG
EG: Envelope Generator
The envelope generator (EG) is used to change the pitch and cutoff frequency over time.
ATTACK knob [0...1023]
The ATTACK specifies the time required for the EG to reach its maximum level once a new note is
played.
DECAY knob [0...1023]
The DECAY specifies the time required for the EG to fall to the preset sustain level once the attack
portion of the EG is complete.
EG INT knob [–100%... 0%...+100%]
Adjusts the intensity of the EG.
Turning the knob to the right will increase the intensity.
When set to a negative value, the EG will be applied in the negative direction.
TARGET switch [PITCH, PITCH 2, CUTOFF]
This sets what the EG will be applied to.
PITCH: Applies the EG to the pitch of VCO 1, VCO 2 and the MULTI ENGINE.
PITCH 2: Applies the EG to the pitch of VCO 2.
CUTOFF: Applies the EG to the cutoff frequency of the FILTER.
0
Attack Level
Time
Note on Note o
Level
Sustain
Level
Attack
Time
Decay
Time
Release
Time