Kracht GmbH Removal | 8
88046020002 37 / 46
8.2 Removal
a) Depressurise and de-energize the system.
b) Close existing shut-off elements upstream and downstream of the device.
c) Open existing drain elements and loosen connection lines. Collect and dispose of dis-
charging medium so that no hazard arises for persons or environment.
d) Dismantle the device.
ð Pull the plug off the housing.
ð Plate structure: Release the unit from the connection plate.
ð Pipe connection: Loosen the pipe connections from the unit and, if applicable, take
the unit off the holding fixture..
e) Clean the device
f) Close the device connections and lines to prevent dirt penetration.
NOTICE
The concrete procedure for cleaning depends on the media being used.
a) See the safety data sheet of the media in use.