BA 35203_04 * 3.0 * 35203_04_05_Bedienung.fm 5-43
Operation 5
Putting an attachment into continuous operation
Continuous operation is used for movements/procedures over a long
period of time or operation of hydraulic motors (for example a rotary
broom) or for operation of attachments with an integrated control valve
adjusted to maximum oil flow, with an unpressurized return.
1. Pick up the attachment and safely lock it
see “Pick up the attachment” on page 5-58,
see “Locking the attachment” on page 5-41.
2. Lower the loader unit and apply the parking brake.
3. Stop the engine, but do not switch off ignition.
4. Release the pressure at the plug couplings
see “Releasing the pressure at the plug couplings” on page 5-66.
5. Switch off the starter and remove the starting key.
6. Connect hose pipes A and B between the attachment and the
quickhitch facility.
7. Start the diesel engine.
Information
Restart lock in continuous operation!
Continuous operation is automatically disabled for safety reasons when
the diesel engine is restarted!
When restarting the vehicle, the continuous operation must be
reactivated!
Information
In order to avoid loss of output, switch off continuous operation if it is no
longer required.
Fig. 145
B A
A
90
III
F
89
B
2
Switching on continuous operation
1. Disable the lock for the work
hydraulics/road travel. To do this:
slide the lock in toggle switch 89
downward and press the toggle switch
to position A.
2. Slide the lock in switch 90 downward
and press the switch to position B.
Symbol F/2 appears in
the digital display.
Continuous operation is
enabled.
Oil pressure builds.