7-80 BA 35203_04 * 3.0 * 35203_04_07_Wartung.fm
7 Maintenance
Monitoring of the SCR catalytic converter:
Fill level of urea solution
The warning messages are issued at a fill level of the urea tank below 15%.
4
Fig. 303
G
66
Symbol
in field G
Message Result
In the field G of the digital display, no symbol appears, no
warning light
lights up and no acoustic signal sounds.
Normal operating conditions
The exhaust after-treatment is working in the
permissible range.
Symbol G/4 appears continuously.
Caution!
Fill level of the urea is below 15%.
Top off urea as soon as possible
see “Refueling with urea solution” on
page 7-88.
Symbol G/4flashes.
Caution!
Fill level of the urea is below 10%.
Top off urea.
Symbol G/4flashes (0.5 Hz).
Warning light 66
lights up continuously.
An acoustic signal sounds.
Caution!
The fill level of the urea is below 5%.
Top off urea immediately.
Symbol G/4flashes (1 Hz).
Warning light 66
lights up continuously.
An acoustic signal sounds.
Caution! Critical condition
Fill level below 5% for longer than 10 minutes.
Diesel engine goes into protective functions
and performance is reduced by 30%.
Top off urea immediately.
Symbol G/4flashes (2 Hz).
Warning light 66
flashes.
An acoustic signal sounds.
Caution! Critical condition
Fill level below 5% for longer than 15 minutes.
Diesel engine goes into protective functions
and performance is reduced by 30%.
Top off urea immediately.
Symbol G/4flashes (2 Hz).
Warning light 66
flashes.
An acoustic signal sounds.
Caution! Extremely critical condition
Fill level below 5% for longer than 20 minutes.
Diesel engine goes into protective functions
and performance is reduced by 30%.
The speed of the diesel engine is limited.
(1200 rpm).
Top off urea immediately.
4
66
4
66
4
66
4
66
4

Table of Contents