PT-871/2-KIT, PT-871/2xr-KIT, WP-871xr, WP-872xr, PT-871xr, PT-872xr Installing Device
8
To mount the WP-871xr and WP-872xr wall plate :
Insert the device into the in-wall box (note that first you need to connect the DGKAT
2.0 cable and power) and connect the parts as shown in the illustrations below:
EU/UK Versions
US Version
We recommend that you use any of the following standard 1 Gang in-wall junction boxes
(or their equivalent):
US-D: 1 Gang US electrical junction boxes.
EU: 1 Gang in-wall junction box, with a cut-hole diameter of 68mm and depth that
can fit in both the device and the connected cables (DIN 49073).
UK: 1 Gang in-wall junction box, 75x75mm (W, H), and depth that can fit in both
the device and the connected cables
(BS 4662).