O P E R A T I N G
O P E R A T I N G
Machinestatus
Afterswitchingon,anautomaticselftestisperformedtoche ckifthe
 capsuleholderisinserted(withreedswitch)
 NTCisconnected,
 NTCisshortcircuited,
 thethermoblockreachestheworkingtemperatureinabout30seconds.
OperatingmodesanddetectedfailuresareindicatedbyLEDsignalsofthepowerbutton
aslisted inthefollowingtable:
Operatingmodes
Powerbut ton
LEDsignals
Economymode/Off —
Heatingup/selftest re d,blinki ng,approx.30sec.
Ready gr een,steady
Afterbeveragepreparation(cool
downtime)
re d,blinki ng,approx.5sec.
Descalingreadyandduringdes
calingcyc le
gr een,slowblinking
Erro rmode re d,rapidblinking