Bleeding the cooling system
To completely bleed the cooling system, the motorcycle must be raised approx. 50 cm
(20 in) in the front.
Remove the radiator cap [1] and bleeder screw [2].
Completely fill the radiator with cooling liquid. Mount the radiator cap and move the motor-
cycle into a horizontal position again. Fill the compensating tank with cooling liquid until it
reaches a level between the MIN and MAX mark. Close the compensating tank.
61
2
Add cooling liquid until it runs out of the vent holes without bubbles and immediately mount
the screw to prevent air from entering the radiator.