43PERIODIC SERVICE
ENGLISH
2. To slow charge the battery, connect the charger
positive terminal to the battery positive terminal, and
negative to the negative.
3. Quick recharging charges the battery at a high rate
in a short time. As this is only for emergencies.
4. Recharge the battery as early as possible, or battery
life will be extremely shortened.
5. When exchanging an old battery into new one, use
battery of equal specification shown in
"SPECIFICATIONS" section.
A Connect the charger positive terminal to the battery
positive terminal, and negative to the negative.
A When disconnecting the cable from the battery, start
with the negative terminal first.
When connecting the cable to the battery, start with
the positive terminal first.
If reversed, the contact of tools on the battery may
cause a short.
BDirection for long term storage
1. When storing the engine for long periods of time,
remove the battery, adjust the electrolyte to the
proper level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
ELECTRIC WIRING
WARNING
To avoid personal injury or death:
C Shorting of electric cable or wiring
may cause a fire.
A Check to see if electric cables and
wiring are swollen, hardened or
cracked.
A Keep dust and water away from all
power connections.
Loose wiring terminal parts, make
bad connections. Be sure to repair
them before starting the engine.
Damaged wiring reduces the capacity of electrical parts.
Change of repair damaged wiring immediately.
1. Use automobile low voltage wiring cables for this
wiring harness.
2. Use fuse and slow blow fuse as wiring protection.
3. Generally, available current of each fuse and size of
wire in this drawing are recommendable value
showed by Kubota, use suitable size fuses and wires
for each machine to consideration to wiring setting
and connection with another lines.
4. Install slow blow fuse near by battery, and install
fuse box near by key switch.
5. Do not connect any parts which may cause induction
current like motors to AC line.
6. Use heatproof cables, if room temperature around
wire harness become over 75°C (167°F).
7. Remove painting at connecting position before
installation of each cable to any parts.
(1) Thick black cable
(2) Battery case
(3) Earth cable
(1) Plug (A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"