Questions and Answers

  • J
    Jennifer ObrienAug 8, 2025
    Why is the speed incorrect on my KUHN RPB?
    • M
      Marissa TaylorAug 8, 2025
      If the speed displayed on your KUHN Control Unit is incorrect, it might be due to a faulty speed sensor or incorrect sensor adjustment. Verify the speed sensor and wiring function, replacing any worn or damaged parts with genuine KUHN parts immediately. Also, ensure that you carry out the calibration as described in the "Configuration" chapter.
  • H
    Heidi HolderAug 12, 2025
    What to do if the KUHN RPB Control Unit control box does not come on?
    • A
      Alisha WaltersAug 13, 2025
      If your KUHN Control Unit's control box does not turn on and isn't controlling any functions, there could be a faulty electric power supply or the control box itself might be faulty. First, check the plug voltage (12V) and ensure the electrical power cable of the control box is properly connected, referring to the "Assembly and fitting" section. If the issue persists, contact your KUHN authorized dealer.
  • S
    susan18Aug 17, 2025
    What to do if I get a flow alarm on my KUHN Control Unit?
    • K
      Kimberly McgeeAug 17, 2025
      If you are getting a flow alarm on your KUHN Control Unit, try reducing the pump flow and ground speed.
  • A
    Andrea BushAug 21, 2025
    Why am I getting over or underdosage with my KUHN RPB Control Unit?
    • J
      Joshua DunnAug 21, 2025
      If you experience over or underdosage with your KUHN Control Unit, it could be due to an incorrect control box setting. Consult the relevant section in the "Configuration" chapter. If the problem persists, contact your KUHN authorized dealer.
  • K
    Kathryn Perez DDSAug 25, 2025
    What to do if I get a maximum pressure alarm on my KUHN RPB?
    • D
      Dr. Tracy ThomasAug 26, 2025
      If you are getting a maximum pressure alarm on your KUHN Control Unit, check the type of nozzle being used and replace it if necessary. Additionally, try reducing the ground speed.
  • B
    Brian RamseyAug 30, 2025
    What to do if I get a minimum flow alarm on my KUHN RPB?
    • C
      charlescruzAug 30, 2025
      If you are getting a minimum flow alarm on your KUHN Control Unit, try increasing the pump flow and forward speed.
  • M
    Marissa GutierrezSep 3, 2025
    What should I do if I receive a minimum pressure alarm on my KUHN RPB?
    • S
      Sherry WhiteSep 3, 2025
      To address a minimum pressure alarm on your KUHN Control Unit, increase the pump flow and forward speed.