Trouble shooting guide
Control box
RPB
63
Pressure alarm
The alarm indicates the pressure is below/over the set
limit.
Maximum pressure alarm
The control box displays an alarm message.
2 "beeps" sound.
Remedy:
- Check the type of nozzle. Replace if necessary.
or
- Reduce ground speed.
Minimum pressure alarm
The control box displays an alarm message.
2 "beeps" sound.
Remedy:
- Increase the pump flow.
or
- Increase forward speed.
Tank low level alarm
The alarm indicates that the tank level is below the set
limit.
Tank low level prewarning alarm
The control box displays an alarm message.
2 x 3 "beeps" sound.
Tank low level alarm
The control box displays an alarm message.
5 "beeps" sound.